Maintenance Free Lead Acid Battery Box Start To Stop Car Charger
2、Each unit has 18kg/39.7 lbs weight
The Maintenance Free Lead Acid Battery Box Start To Stop Car Charger, 12v 100ah lead-acid batteries are free of maintenance, consumers can directly use them without any other complex steps. Because of its low self-discharge and leakage-resistant advantages, each lead-acid device provides safe and stable power.
The deep cycle battery lead acid plates are an important component for charging. With high power feature makes the lead-acid battery perfect for vehicles starting. Our factory produces many size chargers for different cars, we also accept personalized services.

Parameter
| No. | Model No. |
Volts(V) |
Capacity ah(20H) |
RC MIN |
CCA(BCI) -18℃ |
Dimension(mM) | weight | |||
| Lenth | Width | Herght | TH | |||||||
| 1 | 38B20R | 12V | 36Ah | 55 | 310A | 197 | 130 | 202 | 227 | 10.4 |
| 2 | 38B20L | 12V | 36Ah | 55 | 310A | 197 | 130 | 202 | 227 | 10.4 |
| 3 | 46B24R | 12V | 45Ah | 71 | 325A | 238 | 128 | 200 | 222 | 12.6 |
| 4 | 46B24L | 12V | 45Ah | 71 | 325A | 238 | 128 | 200 | 222 | 12.6 |
| 5 | 46B24RT | 12V | 45Ah | 71 | 325A | 238 | 128 | 200 | 222 | 12.6 |
| 6 | 46B24LT | 12V | 45Ah | 71 | 325A | 238 | 128 | 200 | 222 | 12.6 |
| 7 | 46B24YD | 12V | 45Ah | 71 | 325A | 238 | 128 | 200 | 222 | 12.6 |
| 8 | 58500R | 12V | 50Ah | 90 | 380A | 253 | 183 | 155 | 175 | 13.8 |
| 9 | 85500R | 12V | 55Ah | 85 | 400A | 232 | 173 | 186 | 208 | 14.8 |
| 10 | 55415L | 12V | 54Ah | 88 | 265A | 290 | 175 | 175 | 175 | 16.6 |
| 11 | L2400L | 12V | 60Ah | 108 | 525A | 242 | 175 | 190 | 190 | 16.5 |
| 12 | 55D26R | 12V | 60Ah | 100 | 530A | 260 | 175 | 200 | 222 | 18 |
| 13 | 55D26L | 12V | 60Ah | 100 | 530A | 260 | 175 | 200 | 222 | 18 |
| 14 | 55D23R | 12V | 60Ah | 100 | 450A | 232 | 173 | 200 | 225 | 16.9 |
| 15 | 55D23L | 12V | 60Ah | 100 | 450A | 232 | 173 | 200 | 225 | 16.9 |
| 16 | 57069L | 12V | 70Ah | 113 | 570A | 278 | 175 | 190 | 190 | 20 |
| 17 | 58043L | 12V | 80Ah | 160 | 640A | 315 | 175 | 190 | 190 | 21.8 |
| 18 | 95D31R | 12V | 80Ah | 140 | 620A | 302 | 173 | 198 | 222 | 21.5 |
| 19 | 95D31L | 12V | 80Ah | 140 | 620A | 302 | 173 | 198 | 222 | 21.5 |
| 20 | 78-600 | 12V | 69Ah | 115 | 580A | 260 | 179 | 185 | 185 | 17.2 |
| 21 | 58815L | 12V | 88Ah | 165 | 680A | 353 | 175 | 190 | 190 | 24.5 |
| 22 | N100L | 12V | 100Ah | 185 | 520A | 409 | 170 | 209 | 234 | 26 |
| 23 | N120L | 12V | 120Ah | 225 | 480A | 520 | 176 | 213 | 234 | 28 |
| 24 | N120D | 12V | 120Ah | 285 | 630A | 520 | 176 | 213 | 234 | 31.5 |
| 25 | N135 | 12V | 135Ah | 325 | 950A | 410 | 176 | 213 | 234 | 34 |
12v Lead Acid Battery
1. No maintenance requirement, user-friendly device.
2. Powerful for car to start up.
3. With various capacities from 30Ah to 130Ah.



Lead-acid Automotive Starting Batteries
Industry trends indicate that AGM (absorbed glass mat) technology can triple the cycle life of starting batteries compared to traditional batteries, while batteries specifically designed for start-stop systems have a charge acceptance rate 2.5 times that of conventional products. Lead-carbon battery technology replaces some of the negative electrode material with carbon, improving low-temperature starting performance by 30%. Intelligent battery management systems are integrating voltage, temperature, and internal resistance monitoring modules, achieving a remaining life prediction accuracy exceeding 85%.
In terms of material innovation, rare earth alloy grids reduce corrosion rates by 40%, while titanium alloy current collectors reduce weight by 20%. In terms of manufacturing processes, continuous belt casting technology increases grid production efficiency by fivefold, and 3D printing technology enables precise control of the plate pore structure. Regarding testing standard upgrades, the latest version of SAE J537 adds dynamic operating condition testing to simulate performance under real vehicle loads.


Installation Policy
Solar energy system products require professional technicians to install. For safety reasons, we do not recommend that customers install solar products themselves unless they are professional technicians.
We can provide technical support during the installation process. If you have any questions, please send us the relevant photos and videos for communication and check. We will provide online technical services in time.

12v Lead Acid Replacement Certificate

12v Lead Acid ReplacementPakaging

Compatible Inverters

FAQ
Q: Has the battery received any safety certifications?
A: Yes, our batteries have obtained various safety certifications, including UN38.3, MSDS,CE, FCC
Q: How can I obtain a sample to evaluate the quality?
A: You can reach us through online channels or by adding our WhatsApp/WeChat to buy.
Q: Can you tell me about your payment terms?
A: Usually, 100% payment before producing for sample order. For big order payment, we accept a 30% deposit and 70% balance before delivery. We will provide you with photos of the products and packaging before you make the final payment.
About us


Customer Case

May be you will like
Hot Tags: maintenance free lead acid battery box start to stop car charger, China maintenance free lead acid battery box start to stop car charger manufacturers, suppliers, factory
You Might Also Like
Car Start-up Lead-acid Lead Acid Battery Charger 12 ...
Standard Car Marine Lead Acid 12V Battery Rechargeab...
Sealed 12V Lead Acid Battery Cells Maintenance Free ...
Universal Power Car Starting 12V 100Ah Lead Acid Car...
Multiple Electric Car Lead Acid Batteries 30Ah 40Ah ...
Strong Start Capability 12V Lead Acid Battery Mainte...
Send Inquiry




































































































